This article was first published in 2005.
	
			 | 
		
	
	
In any electrical system, relays are amongst the most useful of components. 
They let you control heavy loads with light-weight switches, allow one device to 
be switched off at the same time as another is switched on, are very hard to 
blow-up, and are cheap and widely available. That’s a damn good list of 
attributes!
So how do you use them?
What’s a Relay?
	 
	
	
	
A relay is just a small switch whose movement is caused by the action of an 
electromagnet inside. When power is applied to the relay’s coil, the 
electromagnet comes alive and pulls across the switching contacts.
Relay Types
Single Pole, Single Throw
The simplest relay is a single pole, single throw (SPST) design. This 
designation refers to the switching part of the relay where when it's activated, 
one wire (a "single pole") can be connected only one way (a "single throw"). 
Just like an on/off switch, when you power up the relay's coil, the connection 
is made; when you unpower the coil, the connection is broken. 
	 
	
	
	
In this diagram the relay's coil is yellow. Near to the coil you can see a 
switch, which is open. This is called a Normally Open contact - it's open when 
there's no power being applied to the relay. When power is applied to the 
relay’s coil, the single contact closes. This is a Single Pole Single Throw 
relay - SPST. SPST relays have four terminals - two are to power the coil and 
the other two are the connections for the internal switch. As you can see, there 
is no electrical connection between the pair of contacts for the coil and the 
pair of contacts for the switching side of the relay.
	 
	
	
	
On automotive SPST relays, the pins are given standardised numbers. The coil 
connections are 85 and 86, while the two connections for the internal switch are 
30 and 87. However, most general purpose relays don’t have any numbers on the 
pins – instead the functions of the pins are shown on a little diagram on the 
body of the relay.
The most common use for a SPST relay is to use a small electrical current to 
control a large electrical current. For example, a radiator fan might be 
triggered by a temperature switch. The temp switch is capable of flowing only 2 
amps, but the radiator fan at switch-on takes 15 amps (and then settles back to 
8 amps continuous). 
	 
	
	
	
If you wire the radiator fan to the switch like this, after a few weeks the 
switch would fail – its contacts are being hugely overloaded. 
	 
	
	
	
The solution is to add a SPST relay that is wired into the circuit like this. 
Neither the relay coil nor the switching part of the relay have polarities – 
both can be connected either way around to 12V and Ground. As we said earlier, a 
relay is very hard to blow-up!
Single Pole, Double Throw
	 
	
	
	
But wouldn't it be good if we had a contact that was broken at the same time 
as the switch was made? That's what happens in the Single Pole, Double Throw 
design. Another contact has been added that is Normally Closed. When the relay 
is energised, this contact is broken and the other one (the Normally Open 
contact) is closed. We still have only a single pole to be switched, but now it 
can be connected two ways - a double throw design. This type of relay is 
therefore called a Single Pole, Double Throw relay. As you can see, it has both 
Normally Open (NO) and Normally Closed (NC) contacts. Some people call this a 
changeover relay.
	 
	
		
			
		
		
	 
	
	
A SPDT relay allows you to control two devices, switching one off as the 
other is switched on. A recent example of where I needed to use a relay in this 
way is in a fuel system that needed to be switched between two different fuel 
pressures. To raise the fuel pressure, a solenoid valve had to be turned off and 
at the same time, a fuel pump needed to be switched on. Both devices draw a fair 
amount of current so a heavy duty automotive relay was used. 
SPDT automotive relays use the following codes for their pins: the coil 
connections are again 85 and 86, the normally closed output is 87a, the normally 
open output is 87 and the input is 30.
	 
	
	
	
The circuit diagram for the fuel system relay looks like this. Power is 
normally supplied to the solenoid through the Normally Closed (NC) relay 
contact, energising the solenoid. But when the relay’s coil is activated (by 
closing the High/Low Fuel Pressure switch), the relay pulls the contact across, 
switching off the solenoid and switching on the fuel pump. The High/Low Fuel 
Pressure switch has to handle only enough current to switch the relay’s coil, so 
this can be a light-duty switch (eg a boost pressure switch or a microswitch). 
Double Pole, Double Throw
	 
	
	
	
A Double Pole, Double Throw relay allows you to switch two different circuits 
simultaneously. The 'Double Pole' bit just means that it has two separate inputs 
that can be switched - and we now know what the 'double throw' stuff means. With 
this type of relay you can:
- turn on two completely independent circuits
- turn one off and one on
- turn off two completely independent circuits
These relays are less common in automotive aftermarket use and so don’t have 
coded numbers for the pins.
So what use is a DPDT relay, then? Again, I’ll use an example from a recent 
car modification I have been working on. What was needed was the on-demand 
disconnection of two oxygen sensor input signals to the ECU. The two signal 
wires from the oxy sensors to the ECU needed to be kept completely separate, so 
they couldn’t be joined together and a SPST relay used. Instead a DPDT relay was 
used. (It didn’t actually have to be a double throw design, but DPDT relays are 
more common than SPDT designs.)
Using a Relay
	 
	
	
	
Using a relay is made a lot simpler if you follow these steps.
Draw a circuit diagram. The first step is to draw a simple circuit 
diagram showing where the wires go. Which wires go to the relay coil, which to 
the Normally Open and Normally Closed contacts of the relay?
Decide what type of relay is needed. If just one connection needs to be 
switched on and off, you’ll use a SPST design. If two connections need to be 
switched, a DPST or (more commonly) a DPDT design will be the one to use. A 
changeover (where one device is switched off and the other switched on) can use 
a SPDT or a DPDT design. 
Work out the functions of each pin. If it’s a standard automotive relay, 
read the numbers. If it’s a general purpose relay, look for the diagram on the 
relay body. If neither of these apply, by careful use of a short-circuit 
protected power supply and a multimeter, you can work out the functions of each 
pin. (Unless you use too high a test voltage, you can’t damage the 
relay!)
Wire the relay coil first. If you wire the relay’s coil first, you’ll be 
able to check that the relay is working by listening to its click. 
	
	
		
			
				
				
How Complex?
	 
	 
	
	
It’s easy to think of relays as being suitable for just simple car 
modifications, but that’s not always the case.  
This circuit shows the use of two relays that deactivate traction control 
without affecting ABS or stability control. The system works by connecting the 
un-driven wheel ABS sensor outputs to the driven wheel ECU inputs, so that the 
ECU cannot see a speed difference between the undriven and driven wheels. The 
modification is automatically switched off whenever the brakes are applied, or 
by a manual on/off switch. This diagram shows only half of the system - the 
complete the system just mirror-images the wiring for the other side of the car.  
The total cost of the modification was well under AUD$30 – relays are cheap! 
For more on this approach, see Modifying Electronic Car Handling Systems, Part 3
			  | 
		
	
	
Relay Specifications
In addition to its contact configuration (SPST, DPDT, etc) there are at least 
three other specifications that are important. 
This refers to the voltage which the relay is designed to have its coil 
triggered by. A nominally 12V relay is fine on car voltages, even though they 
can extend as high as 13.8V. However, you shouldn’t use a 5V coil relay on a 12V 
system. (But note that a 24V relay, if it’s a sensitive design, will often work 
fine on 12V!)
This is the amount of current the relay coil will draw when energised. This 
can be expressed directly in milliamps, or indirectly as a coil resistance. A 
very sensitive relay might have a coil resistance of 360 ohms. 13.8 volts 
divided by 360 ohms gives a coil current of 0.038 amps, or 38 milliamps. In 
other words, the switch that you’re using to operate the relay has to handle 
just 38 milliamps. But this is a very low value of required current. A typical 
automotive relay is more likely to have a coil resistance of 80 ohms, giving a 
coil current flow of 170 milliamps. (13.8/80 = 0.17 amps)
	 
	
	
	
This spec refers to the max current that a relay’s contacts can handle. To 
avoid arcing, you should use a factor of safety where the max current of your 
switched circuit (even when it first switches on with a current gulp) is less 
than the relay’s spec. Automotive relays are available with current ratings like 
25, 30 and even 60 amps. Be careful when checking max current specs that the 
listing is for the DC at or above the voltage you’ll be using – ie, in cars, 
13.8V. For example, a relay rated at 10 amps at 240V AC is not the same as one 
rated at 10 amps at 12V DC. 
Other specs that you might fine listed include life (ie how many millions of 
operations the relay will do before failure) and perhaps response time.
Conclusion
	 
	
	
	
Relays can be useful in nearly every electrical or electronic car 
modification. Get your head around their use and you’ll never regret having 
spent the time to find out how they can be used.
	
	
		
			
				
				
A Relay-based Immobiliser
Once you’ve got familiar with relays, you might want to try out this – a 
relay-based immobiliser. It works very well and is very hard for a thief to 
bypass – see The World's Best DIY Immobiliser
			  |